Intake Manifold Assembly
Intake Manifold AssemblyDisassembly
1. Remove the fuel infection supply manifold.
2. Remove the fuel injectors from the fuel injection supply manifold.
3. Discard the two O-ring seals from each fuel injector. Install new O-ring seals.
4. Remove the engine noise shield.
5. Remove the water crossover tube.
^ Inspect and install new gaskets as necessary.
6. CAUTION: If the engine has been internally damaged and metal or other foreign material has entered the manifold, it is recommended the manifold be discarded.
Inspect all external and internal surfaces of the intake manifold.
^ Inspect for cracks or other damage.
^ Inspect for foreign material inside of the manifold.
^ Clean the intake manifold with a suitable cleaner.
Assembly
1. Install the water crossover tube.
2. Install the engine noise shield.
3. NOTE: Lubricate the new O-ring seals with clean engine oil, to aid installation.
Install the fuel injectors into the fuel injection supply manifold.
4. Install the fuel injection supply manifold.