Auxiliary Climate Control Housing-Hybrid
REMOVAL AND INSTALLATION
Auxiliary Climate Control Housing
Material
Removal and Installation
1. With the vehicle in NEUTRAL, position it on a hoist. Description and Operation
2. Recover the refrigerant. Service and Repair
3. Remove the 2 auxiliary evaporator outlet and inlet line rear fitting nuts and disconnect the fittings.
^ Discard the 0-ring seals.
^ To install, tighten to 8 Nm (71 lb-in).
4. Remove the 2 auxiliary line floorpan bracket nuts.
^ To install, tighten to 6 Nm (53 lb-in).
5. Remove the LH quarter trim panel.
6. Remove the LH D-pillar trim panel. Exterior Moulding / Trim
7. NOTE: When installing, tighten the screws on the High Voltage Traction Battery (HVTB) first to make sure the duct is sealed correctly. No air flow loss.
8.Remove the 2 auxiliary climate control upper housing nuts.
^ To install, tighten to 7 Nm (62 lb-in).
9. Remove the 2 auxiliary climate control housing bolts.
^ To install, tighten to 7 Nm (62 lb-in).
10. Disconnect the electrical connectors and remove the auxiliary climate control housing.
11. To install, reverse the removal procedure.
^ Install new 0-ring seals.
^ Lubricate the refrigerant system with the correct amount of clean PAG oil. Service and Repair
12. Evacuate, leak test and charge the refrigerant system. Testing and Inspection