Auxiliary Evaporation Outlet and Inlet-Front
Auxiliary Evaporator Outlet and Inlet Line - Front
Material
Front Connection
Intermediate Connection
Removal and Installation
NOTE: Installation of a new suction accumulator is not required when repairing the A/C system, except when there is physical evidence of contamination from a failed A/C compressor or damage to the receiver/drier.
1. With the vehicle in NEUTRAL, position it on a hoist.
2. Recover the refrigerant. Refrigerant
3. Remove the front auxiliary evaporator outlet line front fitting nut and disconnect the fitting.
^ Discard the 0-ring seal and gasket seal.
^ To install, tighten to 8 Nm (71 lb-in).
4. Remove the front auxiliary evaporator inlet line front fitting nut and disconnect the fitting.
^ Discard the 0-ring seal.
^ To install, tighten to 8 Nm (71 lb-in).
5. Remove the front auxiliary evaporator outlet and inlet line bracket bolt and the front auxiliary evaporator outlet and inlet lines.
^ To install, tighten to 6 Nm (53 lb-in)
6. Remove the auxiliary evaporator line bracket nut and detach the bracket.
7. Remove the 2 auxiliary line bracket retainers and the front auxiliary evaporator outlet and inlet lines.bracket.
8. To install, reverse the removal procedure.
^ Install a new gasket seal and new 0-nag seals.
^ Lubricate the refrigerant system with the correct amount of clean PAG oil. Refrigerant
9. Evacuate, leak test and charge the refrigerant system.