Variable Valve Timing Solenoid: Service and Repair
VARIABLE CAMSHAFT TIMING (VCT) OIL CONTROL SOLENOIDRemoval and Installation
1. Disconnect the battery ground cable.
2. Disconnect the variable camshaft timing (VCT) oil control solenoid electrical connector.
3. Remove the grommet.
4. Remove the bolt and the VCT oil control solenoid.
- To install, tighten to 5 Nm (44 lb-in).
5. To install, reverse the removal procedure