Operation CHARM: Car repair manuals for everyone.

Variable Valve Timing Solenoid: Service and Repair

VARIABLE CAMSHAFT TIMING (VCT) OIL CONTROL SOLENOID







Removal and Installation
1. Disconnect the battery ground cable.
2. Disconnect the variable camshaft timing (VCT) oil control solenoid electrical connector.
3. Remove the grommet.
4. Remove the bolt and the VCT oil control solenoid.
- To install, tighten to 5 Nm (44 lb-in).

5. To install, reverse the removal procedure