Test D: DTC B2784 or DTC B2783 - A/C Humidity Sensor Open Circuit or Short to Ground
PINPOINT TEST D: DTC B2784 OR DTC B2783 - A/C HUMIDITY SENSOR OPEN CIRCUIT OR SHORT TO GROUNDD1-D2:
D2-D4:
D5-D7:
D7-D9:
D10:
Normal Operation
Under normal operation, the A/C humidity sensor is grounded through circuit RH111 (GY/BU). A 5-volt reference voltage is supplied to the A/C humidity sensor from the electronic automatic temperature control (EATC) module through circuit VH413 (WH/BU). The EATC module receives the humidity value through circuit LH115 (WH).
Possible Causes
- An open in circuit RH111 (GY/BU), VH413 (WH/BU) or LH115 (WH)
- A short together in circuit RH111 (GY/BU) and LH115 (WH)
- A short to ground in circuit LH115 (WH)
- A short to voltage in circuit VH413 (WH/BU)
- A/C humidity sensor
- EATC module