Test C: All Door Locks Are Inoperative From One Switch
PINPOINT TEST C: ALL DOOR LOCKS ARE INOPERATIVE FROM ONE SWITCHC1-C3:
Normal Operation
The door lock control switches provide a ground, circuit GD133 (BK) or circuit GD151 (BK/GN) for the smart junction box (SJB) lock and unlock signal circuits CPL42 (GY/YE) and CPL43 (VT/GY). The door lock actuator circuits CPL11 (GY/BN), CPL51 (BU/GN) and CPL52 (VT/GY) are at ground potential in the SJB when the lock and unlock relays are not energized.
When the SJB receives a lock request through circuit CPL42 (GY/YE), the SJB processes the lock request and energizes the all lock relay, supplying voltage to circuit CPL11 (GY/BN) to lock the doors. Circuits CPL51 (BU/GN) and CPL52 (VT/GY) are at ground potential within the SJB.
When the SJB receives an unlock request through circuit CPL43 (VT/GY), the SJB processes the unlock request and energizes the all unlock relay and driver unlock relay supplying voltage to circuits CPL52 (VT/GY) and CPL51 (BU/GN) to unlock the doors. Circuit CPL11 (GY/BN) is at ground potential within the SJB.
Possible Causes
- Circuit GD133 (BK) open
- Circuit GD151 (BK/GN) open
- Door lock control switch
- SJB