Test D: A Single Power Window Is Inoperative - RH Front
PINPOINT TEST D: A SINGLE POWER WINDOW IS INOPERATIVE - RH FRONTD1-D3:
D3-D4:
D4-D5:
D5 Continued:
Normal Operation
The RH front window control switch receives power from the LH front window control switch through circuit 400 (LB/BK). The RH front window control switch transfers power to the RH front window motor through circuit 334 (RD/YE) and ground through 333 (YE/RD) to operate the RH front window downward. To move the RH front window UP, the RH front window control switch transfers power through circuit 333 (YE/RD) and ground through 334 (RD/YE).
When operating the RH front window from the LH front window control switch, power is sent to the passenger front window control switch through circuit 314 (TN/LB) and ground through 313 (WH/YE) to operate the RH front window. To move the RH front window UP, the LH window control switch provides power through circuit 313 (WH/YE) and ground through 314 (TN/LB) to operate the passenger front window upward.
Possible Causes
- Open in circuits 400 (LB/BK), 193 (YE/LG), 313 (WH/YE), 314 (TN/LB), 333 (YE/RD) or 334 (RD/YE)
- LH front window control switch
- RH front window control switch
- RH front window motor