Test K: The Turn Signal Lamps Are Inoperative
PINPOINT TEST K: THE TURN SIGNAL LAMPS ARE INOPERATIVEK1-K2:
K2-K4:
K4-K6:
Normal Operation
The electronic flasher receives voltage from the central junction box (CJB) fuse 27 (15A) through circuit 295 (LB/PK). Voltage is then routed to the multifunction switch through circuit 44 (LB) (turn lamps) and circuit 385 (WH/RD) (hazard lamps). When the multifunction switch is placed in the LH or RH TURN position, voltage is routed to the appropriate turn lamps. The electronic flasher receives ground through circuit 57 (BK).
Possible Causes
- Fuse
- Circuit 44 (LB) open or short to ground
- Circuit 57 (BK) open
- Circuit 295 (LB/PK) open
- Circuit 385 (WH/RD) short to ground
- Multifunction switch
- CJB