Test N: The RH/LH Turn Indicator Is Never On
PINPOINT TEST N: THE RH/LH TURN INDICATOR IS NEVER ONNormal Operation
When the multifunction switch is placed in the RH TURN position, voltage is supplied to the instrument cluster (IC) through circuit 2 (WH/LB). When the multifunction switch is placed in the LH TURN position, voltage is supplied to the instrument cluster (IC) through circuit 3 (LG/WH).
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Instrument cluster (IC)