Operation CHARM: Car repair manuals for everyone.

Anti-Theft Security Access




Anti-Theft Security Access





NOTE: The anti-theft security access procedure is used to obtain Passive Anti-Theft System (PATS) security access. PATS security access must be granted to erase ignition key codes, program ignition key codes, enable/disable unlimited key mode, set unlimited transponder key ID, reset Instrument Cluster (IC) or PCM parameters and enable/disable the spare key programming switch (PID SPAREKEY). The anti-theft security access procedure invokes a 10-minute time delay prior to granting security access during which the scan tool must remain connected to the vehicle. Once security access is granted, a security access command menu is displayed which offers various command options.

NOTE: Once security access has been granted, multiple security access commands should be executed (if necessary) prior to exiting the command menu. This avoids an additional security access procedure and the associated 10-minute time delay.

NOTE: If anti-theft security access has been entered to reset parameters, make sure to cycle the ignition several times, holding the key in each position for a minimum of 3 seconds. The vehicle may not start until the key has been cycled a minimum of 3 times. This allows the modules to send and receive the IDs after the parameter resets have occurred.

NOTE: When using the Integrated Diagnostic System (IDS), the IC and the PCM parameters are reset at the same time.

NOTE: Once security access has been granted for either the IC or the PCM, you can toggle between the 2 modules without having to wait an additional 10 minutes (if not using the IDS).

1. Turn the key from the OFF position to the ON position.

2. From the scan tool, enter TOOLBOX. Select BODY - SECURITY - PATS Functions and follow the on-screen instructions to ENTER SECURITY ACCESS.

3. After the 10-minute security access procedure is completed, follow the on-screen instructions and a new menu is displayed with command options. Select only those functions required before exiting out of this menu. Do not select more functions than the procedure calls for. Once exited out of this menu, the security access procedure must be repeated again to carry out additional commands.