Pinpoint Test F: The Occupant Classification System Module (OCSM) Does Not Respond To The Scan Tool
Communications Network
Pinpoint Tests
Pinpoint Test F: The Occupant Classification System Module (OCSM) Does Not Respond To The Scan Tool
Refer to Wiring Diagram Set 14, Module Communications Network for schematic and connector information. Diagrams By Number
Refer to Wiring Diagram Set 46, Supplemental Restraint System for schematic and connector information. Diagrams By Number
Normal Operation
The Occupant Classification System Module (OCSM) communicates with the scan tool through the High Speed Controller Area Network (HS-CAN).
This pinpoint test is intended to diagnose the following:
- Fuse
- Wiring, terminals or connectors
- OCSM
PINPOINT TEST F: THE OCSM DOES NOT RESPOND TO THE SCAN TOOL
WARNING: Never probe the electrical connectors on safety belt buckle/retractor pretensioners or adaptive load limiting retractors. Failure to follow this instruction may result in the accidental deployment of the safety belt pretensioners or adaptive load limiting retractors, which increases the risk of serious personal injury or death.
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
NOTE: Failure to disconnect the battery when instructed will result in false resistance readings. Refer to Battery.
NOTE: Most faults are due to connector and/or wiring concerns. Carry out a thorough inspection and verification before proceeding with the pinpoint test. Inspection and Verification
-------------------------------------------------
F1 CHECK THE OCSM VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
NOTE: The Supplemental Restraint System (SRS) must be fully operational and free of faults before releasing the vehicle to the customer.
- Ignition OFF.
- Depower the SRS. Refer to Restraint Systems.
- Disconnect: OCSM C3159.
- Deactivate the SRS. Refer to Restraint Systems.
- Repower the SRS. Refer to Restraint Systems.
- Ignition ON.
- Measure the voltage between the OCSM C3159-1, circuit CBP17 (BN/GN), harness side and ground.
- Is the voltage greater than 10 volts?
Yes
GO to F2.
No
VERIFY the Smart Junction Box (SJB) fuse 17 (10A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the Wiring Diagrams to identify the possible causes of the circuit short. Diagrams By Number
REACTIVATE the SRS. REFER to Restraint Systems. CLEAR the DTCs. REPEAT the network test with the scan tool.
-------------------------------------------------
F2 CHECK THE OCSM GROUND CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: Negative Battery Cable.
- Measure the resistance between the OCSM C3159-14, circuit GD145 (BK/BU), harness side and ground.
- Is the resistance less than 5 ohms?
Yes
GO to F3.
No
REPAIR the circuit. CONNECT the negative battery cable. REACTIVATE the SRS. REFER to Restraint Systems. CLEAR the DTCs. REPEAT the network test with the scan tool.
-------------------------------------------------
F3 CHECK THE HS-CAN CIRCUITS BETWEEN THE OCSM AND THE DLC FOR AN OPEN
- Measure the resistance between the OCSM C3159-18, circuit VDB04 (WH/BU), harness side and the DLC C251-6, circuit VDB04 (WH/BU), harness side.
- Measure the resistance between the OCSM C3159-9, circuit VDB05 (WH), harness side and the DLC C251-14, circuit VDB05 (WH), harness side.
- Are the resistances less than 5 ohms?
Yes
CONNECT the negative battery cable. GO to F4.
No
REPAIR the circuit. REACTIVATE the SRS. REFER to Restraint Systems. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.
-------------------------------------------------
F4 CHECK FOR CORRECT OCSM OPERATION
- Disconnect the OCSM connector.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect the OCSM connector and make sure it seats correctly.
- Verify the concern is still present.
- Is the concern still present?
Yes
INSTALL a new OCSM. REACTIVATE the SRS. REFER to Restraint Systems. CLEAR the DTCs. REPEAT the network test with the scan tool.
No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. REACTIVATE the SRS. REFER to Restraint Systems. CLEAR the DTCs. REPEAT the network test with the scan tool.
-------------------------------------------------