Condenser to Evaporator Line
Condenser to Evaporator Line
Removal and Installation
1. Recover the refrigerant.
2. Disconnect the evaporator inlet fitting.
- Discard the O-ring seals.
3. Remove the condenser outlet fitting nut and disconnect the fitting.
- Discard the O-ring seal.
- To install, tighten to 8 Nm (71 lb-in).
4. To install, reverse the removal procedure.
- Install new O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil.
5. Evacuate, leak test and charge the refrigerant system.