SSC, SSD and SSE In Bench Mode
SSC, SSD and SSE in BENCH MODEThe BENCH MODE is also used to test the functionality of pulse width modulated solenoids of the transaxle. During BENCH MODE, the SSC/D/E solenoids can ramp in increments of 25% from 0% to 100% duty cycle and 100% to 0% duty cycle.
The OSC functions for the parameters SSC/D/E allow the technician to choose the following options:
- SSC - Activates SSC to selected values.
- SSD - Activates SSD to selected values.
- SSE - Activates SSE to selected values.
- [00] - sets SSCI DIE duty cycle to 00%
- [25] - sets SSCIDIE duty cycle to 25%
- [50] - sets SSCIDIE duty cycle to 50%
- [75] - sets SSC/D/E duty cycle to 75%
- [100] - sets SSCIDIE duty cycle to 100%
OSC "SSC/DIE" BENCH MODE operates ONLY when:
- VSS and TR sensor are operational.
- No VSS and TR sensor DTCs.
- Transaxle range selector level in P.
- Key ON.
- Engine ON.
- Engine speed at least 1500 RPM.
- Pressure gauge installed (optional).
OSC Command Values:
- [00] - sets SSC/D/E duty cycle to 00%
- [25] - sets SSC/D/E duty cycle to 25%
- [50] - sets SSC/D/E duty cycle to 50%
- [75] - sets SSCIDIE duty cycle to 75%,
- [100] - sets SSCIDIE duty cycle to 100%
- [XXX] - cancels OSC value sent.
- [SEND] - sends the values to PCM.
BENCH MODE Procedure for SSC, SSD and SSE
Follow operating instructions from the NGS menu screen:
- Select"Output State Control."
- Select"Trans-Bench Mode."
- Select"PIDS" to be monitored.
- Monitor all selected PIDs during test.
- Select"Parameters - SSC, SSD, SSE."
- Select Value"0-100%."
- Press"SEND" to send command.
- Select"XXX" to cancel at any time.
- Press"SEND to send command.