DA-6 Compressor
1. Remove the accumulator.2. Drain, measure and record quantity of oil in accumulator.
NOTE: It is not necessary to remove and drain the DA-6 compressor because the compressor only retains a minimum quantity of oil, it doesn't have an oil sump area.
^ If less than 0.085 kg. (3 ounces) add 0.085 kg. (3 ounces) of new oil to the system.
^ If more than 0.085 kg. (3 ounces) add the same amount of new oil as drained.
^ If a new accumulator is installed add 0.085 kg. (3 ounces) additional oil to compensate for that absorbed by the original accumulator desiccant.