RH Window Switch Operation
When the Ignition Switch is in RUN, battery voltage is supplied to the RH Window Switch through the PWR WDO Circuit Breaker and the PNK (76) wires to terminal A. When the UP Switch in the RH Window Switch is operated, battery voltage is supplied to the RH Window Motor through the DK BLU (666) wire. The Motor is grounded through the BRN (667) wire, the DN contact in the RH Window Switch, the TAN (167) wire and the DN contact in the Master Door Lock/
Power Window Switch Assembly. The Motor runs to drive the window up. When the DN Switch in the RH Window Switch is operated, battery voltage is supplied to the RH Window Motor in the opposite direction through the BRN (667) wire. The Motor is grounded through the DK BLU (666) wire, the UP contact in the RH Window Switch, the DK BLU/WHT (166) wire and the UP contact in the Master Door Lock/Power Window Switch Assembly. The Motor runs to drive the window down.