Compressor Replacement
Compressor Mounting:
Remove or Disconnect
1. Negative battery cable.
2. Discharge and recover refrigerant from the system.
3. Drive belt.
4. Refrigerant hose assembly from compressor.
- Cap or plug all open connections.
5. Electrical connectors, as necessary.
6. Bolts (5).
7. Bolt (12).
8. Bolt (15).
9. Bolt (13).
10. Braces (11 and 14).
11. Compressor (1).
- Drain and measure compressor oil.
Install or Connect
1. Compressor (1).
2. Braces (11 and 14).
3. Bolt (13).
4. Bolt (15).
5. Bolt (12).
6. Tighten:
- Bolts (5) to 50 Nm (37 lbs. ft.).
- Bolts (12 and 15) to 84 Nm (62 lbs. ft.).
- Bolt (13) to 65 Nm (48 lbs. ft.).
7. Electrical connectors, as necessary.
8. Refrigerant hose assembly to compressor.
9. Drive belt.
10. Negative battery cable.
11. Refrigerant to the system.
- Check the system for leaks.