Operation CHARM: Car repair manuals for everyone.

Three Way Catalyst Oxygen Storing Capacity

Three-Way Catalyst Oxygen Storage Capacity:









The control module must monitor the Three-Way catalyst system (TWC) for efficiency. In order to accomplish this, the control module monitors the pre-catalyst and post-catalyst oxygen sensors. When the TWC is operating properly, the post-catalyst (2) oxygen sensor will have significantly less activity than the pre-catalyst (1) oxygen sensor. The TWC stores oxygen as needed during its normal reduction and oxidation process. The TWC releases oxygen as needed during its normal reduction and oxidation process. The control module calculates the oxygen storage capacity using the difference between the pre-catalyst and post-catalyst oxygen sensor's voltage levels.

Whenever the voltage levels of the post-catalyst (2) oxygen sensor nears the voltage levels that of the pre-catalyst (1) oxygen sensor, the catalysts efficiency is degraded.

Stepped or staged testing levels allow the control module to statistically filter test information. This prevents falsely passing or falsely failing the oxygen storage capacity test. The calculations performed by the on-board diagnostic system are very complex. For this reason, do not use post catalyst oxygen sensor activity in order to determine the oxygen storage capacity unless directed by the electronic service information.

Three stages are used in order to monitor catalyst efficiency. Failure of the first stage indicates that the catalyst requires further testing in order to determine catalyst efficiency. Failure of the second stage indicates that the catalyst may be degraded. The third stage then looks at the inputs from the pre and post O2 sensors more closely before determining it the catalyst is indeed degraded. This further statistical processing is done to increase the accuracy of oxygen storage capacity type monitoring. Failing the first (stage 0) or second (stage 1) test Does Not indicate a failed catalyst. The catalyst may be marginal or the fuel sulfur content could be very high.

Aftermarket HO2S characteristics may be different from the original equipment manufacturer sensor. This may lead to a false pass or a false fail of the catalyst monitor diagnostic. Similarly, if an Aftermarket catalyst does not contain the same amount of cerium as the original part, the correlation between oxygen storage and conversion efficiency may be altered enough to set a false Diagnostic Trouble Code (DTC).