Manifold Pressure/Vacuum Sensor: Service and Repair
MAP Sensor Electrical Connector:
MAP Sensor:
REMOVAL PROCEDURE
1. Remove the electrical connector.
2. Remove the attaching screws.
3. Remove the Manifold Absolute Pressure (MAP) sensor.
INSTALLATION PROCEDURE
1. Install the MAP sensor using the attaching screws.
Tighten
^ Tighten the attaching screws to 2-4 Nm (35 lb. in.).
2. Install the electrical connector.