Inner Manual Linkage Installation
INSTALLATION PROCEDURE1. Install the parking lock bracket.
- Tighten the parking lock bracket bolt to 31 Nm (23 ft. lbs.).
2. Install the following items:
- The inside detent lever
- Parking lock actuator assembly
- The manual shaft
- Manual shaft retainer
- The hex head nut
- Tighten the nut to 31 Nm (23 ft. lbs.).