EEPROM Programming
1. Take the following steps in order to set-up for the EEPROM Programming.^ The battery is charged.
^ The ignition is ON.
^ The battery and cigarette lighter connection is secure.
^ The Data Link Connector (DLC).
2. Refer to up-to-date Techline terminal and equipment user's instructions.
3. If the VCM fails to program, do the following functions:
^ Check all the VCM connections.
^ Check the Techline terminal and equipment for the latest software version.
^ Try again to program the VCM. If it fails again, replace the VCM.
NOTE: The ignition should always be OFF when installing or removing the VCM connectors.
4. Perform the IAC valve reset procedure with the scan tool. Use misc. test.
5. For a functional check perform one of the steps:
^ Use the Techline terminal and equipment in order to perform the On-Board Diagnostic (OBD) System Check.
^ Refer to Diagnostic System Check.