Temperature Valve Replacement
REMOVAL PROCEDURE
CAUTION: Refer to Battery Disconnect Caution in Cautions and Notices.
1. Disconnect the negative battery cable.
2. Remove the heater/ventilation module.
3. Remove the heater/ventilation module screws.
4. Separate the heater/ventilation module halves.
5. Remove the temperature valve.
INSTALLATION PROCEDURE
1. Install the temperature valve.
2. Install the heater/ventilation module halves.
NOTE: Refer to Fastener Notice in Cautions and Notices.
3. Install the heater/ventilation module module screws.
Tighten
Tighten the screws to 1.6 N.m (14 lb in).
4. Install the heater/ventilation module.
5. Connect the negative battery cable.
Tighten
Tighten the bolt to 17 N.m (13 lb ft).