Expansion (Orifice) Tube Replacement - Auxiliary (C69)
REMOVAL PROCEDURE
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging Service and Repair
2. Disconnect the evaporator tube from the evaporator.
3. Remove the O-ring seal.
4. Disconnect the evaporator tube from the condenser.
5. Remove the O-ring seal.
6. Disconnect the evaporator tube from the auxiliary evaporator hose.
7. Remove the O-ring seal.
8. Remove the evaporator tube.
INSTALLATION PROCEDURE
1. Install the evaporator tube.
2. Coat the new O-ring seal with 525 viscosity refrigerant oil.
3. Install the new O-ring seal.
NOTE: Refer to Fastener Notice in Cautions and Notices.
4. Connect the evaporator tube to the auxiliary evaporator hose.
Tighten
Tighten the evaporator tube to 24 N.m (18 lb ft).
5. Coat the new O-ring seal with 525 viscosity refrigerant oil.
6. Install the new O-ring seal.
7. Connect the evaporator tube to the condenser.
Tighten
Tighten the evaporator tube to 24 N.m (18 lb ft).
8. Coat the new O-ring seal with 525 viscosity refrigerant oil.
9. Install the new O-ring seal.
10. Connect the evaporator tube to the evaporator.
Tighten
Tighten the evaporator tube to 24 N.m (18 lb ft).
11. Charge the system. Refer to Refrigerant Recovery and Recharging Service and Repair
12. Inspect the system for leaks. Refer to Leak Testing. Testing and Inspection