Pressure Cycling Switch Replacement
REMOVAL PROCEDURE
1. Disconnect the electrical connection at the pressure cycling switch.
IMPORTANT: Do not recover the refrigerant. The fitting has a Schrader Valve(R).
2. Remove the pressure cycling switch.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Cautions and Notices.
1. Install the pressure cycling switch.
Tighten
Tighten the pressure cycling switch to 4 N.m (35 lb in).
2. Connect the electrical connection at the pressure cycling switch.