Blower Motor & Fan Replacement - Auxiliary (Suburban)
REMOVAL PROCEDURECAUTION: Refer to Battery Disconnect Caution in Cautions and Notices.
1. Disconnect the negative battery cable.
2. Remove the right rear quarter trim panel.
3. Disconnect the electrical connectors.
4. Remove the screws (3) securing the blower motor (2).
5. Remove the cooling tube.
6. Remove the blower motor.
7. Remove the fan cage from the motor.
INSTALLATION PROCEDURE
1. Install the fan cage to the motor.
2. Install the blower motor (2) to the case.
NOTE: Refer to Fastener Notice in Cautions and Notices.
3. Install the screws (3).
Tighten
Tighten the screws to 1.7 N.m (15 lb in).
4. Install the cooling tube.
5. Connect the electrical connectors, as necessary.
6. Install the right rear quarter trim panel.
7. Connect the negative battery cable.
8. Test the check circuit operation.