Exhaust Gas Recirculation: Service and Repair
REMOVAL PROCEDURECAUTION: Refer to Battery Disconnect Caution in Cautions and Notices.
EGR Control Pressure Sensor:
1. Remove negative battery cables.
2. Remove the vacuum harness assembly.
3. Remove the electrical connector.
4. Remove the mounting bolts.
5. Remove the sensor.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Cautions and Notices.
1. Install the mounting bolts with the sensor.
Tighten
Tighten the mounting bolts to 3.5 N.m (27 lb in).
2. Install the electrical connector.
3. Install the vacuum harness.
4. Install the negative battery cables.