HVAC System - Manual
REMOVAL PROCEDURE1. Remove the instrument pane accessory trim plate.
2. Depress the control assembly retaining tabs, and remove the control assembly from the instrument panel.
3. Remove the vacuum connectors (1), as necessary.
4. Remove the electrical connectors, as necessary.
5. Remove the control assembly bulb from the control assembly and retain.
INSTALLATION PROCEDURE
1. Install the control assembly bulb to the control assembly.
2. Install the electrical connectors, as necessary.
3. Install the vacuum connectors (1), as necessary.
4. Install the control assembly into the instrument panel, ensuring that the control assembly retaining tabs lock into place.
5. Install the instrument panel accessory trim plate.