Rear Window Switch Operation
Place the ignition switch in the RUN position in order to supply voltage to the rear side window switches through the POWER WINDOW circuit breaker, through CKT 1001 (DK GRN) then through the side window lockout switch and through CKT 1307 (DK BLU) to terminal B. Press the UP Switch in order to supply battery voltage to the rear side regulator motor through CKT 668 (DK BLU). The motor is grounded through the following circuits:^ CKT 669 (BRN) -The down contact in the left rear side window switch.
^ CKT 169 (PPL) - The down contact in the left door lock and side window switch.
The right rear motor is grounded through the following circuits:
^ CKT 671 (BRN) - The down contact in the right rear side window switch.
^ CKT 171 (PPL) - The down contact in the left door lock and window switch.
The motor runs in order to drive the window up. Press the down window switch in order to supply battery voltage to the window regulator motor in the opposite direction through CKT 669 (BRN) for the left rear, and CKT 671 (BRN) for the right rear.