Vacuum Control System - HVAC System - Manual
Vacuum System:
Vacuum System
Use the diagnostic table below in order to diagnose the system if the following conditions exist:
^ The airflow through the vents changes modes while driving.
^ The airflow through the vents remains in any mode and is unable to change.
Refer to the vacuum diagrams and the operational charts for the following information:
^ Airflow
^ Air door functioning
^ Vacuum circuits
Inspect the hose connections at the following positions:
^ The vacuum actuators
^ The control head valve
^ The vacuum tank
If the vacuum is less than normal at all positions, remove the tee.
Connect the vacuum gauge line to the tank. Read the vacuum. Refer to the following list for information on the vacuum readings:
^ if the vacuum is still low, the problem lies in the feed circuit to the tank or the tank.
^ if the vacuum is now normal, the problem lies downstream.
^ The vacuum may be less than normal at some positions.
^ If the vacuum is low at one or several of the selector knob positions, a leak is indicated at the circuit(s).
^ The vacuum may be normal at all positions.
^ The malfunction may be caused by improperly connected or plugged lines.
^ If the vacuum is normal and even at all positions, the malfunction may be caused by the vacuum valve(s).
Inspect the specific vacuum circuits using the following steps:
1. Place the selector knob in the malfunctioning position.
2. Inspect the vacuum for the pertinent vacuum actuators.
If the vacuum exists at the actuator but the door does not move, the actuator is defective or the door is mechanically bound.
3. Inspect the vacuum harness first. Determine whether one of the following is the cause:
^ The vacuum harness
^ The vacuum valve is low
^ No vacuum exists at the actuator
Inspect the vacuum harness circuit using the following steps:
1. Disconnect the vacuum harness at the control head.
2. The green line should show the engine vacuum. If the green line does not show the engine vacuum, trace back through the connector to the vacuum tank.
3. Place the selector knob at the involved circuit position in order to check any individual circuit.
4. Inspect for vacuum at the individual circuits.