Operation CHARM: Car repair manuals for everyone.

TP Sensor Output

This check should be performed when TP sensor attaching parts have been replaced. A scan tool can be used to read the TP signal output voltage.

1. Connect digital voltmeter J 39200 from TP sensor connector terminal B (BLK wire) to terminal C (DK Blue wire). Jumpers for terminal access can be made using terminals 1214836 and 12014837.
2. With ignition ON, engine stopped, the TP signal voltage should be less than 1.25 V if more than 1.25 V verify free throttle movement. If still more than 1.25 V, replace TP sensor.
3. Remove the voltmeter and jumpers, reconnect the TP sensor connector to the sensor.