Defroster Valve Replacement
REMOVAL PROCEDURE1. Remove the right windshield garnish molding.
2. Disconnect the vacuum hose from the valve (1).
3. Remove the valve by unsnapping the valve from the heater case.
4. Disconnect the linkage from the valve.
INSTALLATION PROCEDURE
1. Connect the linkage to the valve.
2. Install the valve by snapping the valve to the heater case.
3. Connect the vacuum hose to the valve (1).
4. Install the right windshield garnish molding.