Operation CHARM: Car repair manuals for everyone.

Refrigerant Pressure Sensor / Switch: Service and Repair

PRESSURE CYCLING SWITCH REPLACEMENT

REMOVAL PROCEDURE




1. Remove the air cleaner cover and duct assembly.
2. Disconnect the electrical connector from the A/C pressure cycling switch (4).
3. Remove the A/C pressure cycling switch (4) from the accumulator (2).

INSTALLATION PROCEDURE




1. Using a lint-free clean, dry cloth, carefully clean the sealing surfaces of the liquid line fitting.
2. Lightly coat the new O-ring seal with mineral base 525 viscosity refrigerant oil.

IMPORTANT: DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the new O-ring seal to enter the refrigerant system.

3. Install the new O-ring seal (3).

NOTE: Refer to Fastener Notice in Service Precautions.

4. Install the A/C pressure cycling switch (4) to the A/C accumulator.

Tighten
Tighten the switch to 6 N.m (53 lb in).

5. Connect the electrical connector to the A/C pressure cycling switch.
6. Install the air cleaner and duct assembly.