Passenger Power Window Operation
The passenger
power window switches incorporate window up and down relays. The relay coil feed and supply sides are powered through the RAP fuse supply voltage circuit. The normally closed contacts of each relay is connected to ground. The load side of each of the relays are connected to either side of the
power window motor through the power window up and down circuits. The up and down relay control circuits are connected to the normally closed contacts of the passenger window switch. These contacts are wired in series with the power window master switch, through the power window master switch up and down signal circuits and then to ground when the power window master is placed in the up or down position. This allows for the up and down operation of the passenger power window from the power window master switch. The center pole of the passenger power window switch is also connected to ground and will energize the relay when placed in the up or down position.