Air Flow Meter/Sensor: Service and Repair
MASS AIR FLOW/INTAKE AIR TEMPERATURE (IAT) SENSOR REPLACEMENTREMOVAL PROCEDURE
1. Disconnect the mass air flow/intake air temperature (MAF/IAT) sensor assembly harness connector.
2. Separate the MAF/IAT sensor assembly and the air inlet tube by loosening the hose clamp.
NOTE: Handle the MAF/IAT sensor carefully. Do not drop the MAF/IAT sensor. Do not damage the screen located at the air inlet end of the MAF/IAT. Do not touch the sensing elements. Do not allow solvents and lubricants to come in contact with the sensing elements. Use a small amount of SPO P/N 12345884 lubricant or the soap based equivalent in order to aid in the installation.
3. Disconnect the MAF/IAT sensor assembly from the air cleaner cover by loosening the hose clamp.
INSTALLATION PROCEDURE
IMPORTANT: Ensure to point the flow arrow on the MAF/IAT sensor assembly away from the air cleaner assembly.
NOTE: Refer to Fastener Notice in Service Precautions.
1. Connect the MAF/IAT sensor assembly and the air cleaner cover by tightening the hose clamp.
Tighten
Tighten the clamp to 4 N.m (35 lb in).
2. Connect the MAF/IAT sensor assembly and the air inlet tube by tightening the hose clamp.
Tighten
Tighten the clamp to 4 N.m (35 lb in).
3. Connect the MAF/IAT sensor harness connector.