12 Volt Power Supply Replacement
REMOVAL PROCEDURECAUTION: Refer to Battery Disconnect Caution in Service Precautions.
1. Disconnect the negative battery cable.
2. Remove the instrument panel (IP) extension.
3. Disconnect the electrical connectors (1) from the 12-volt power supply socket (2).
4. Remove the retaining ring (3) from the 12-volt power supply socket by unscrewing the ring.
5. Remove the 12-volt power supply socket from the IP extension.
INSTALLATION PROCEDURE
1. Install the 12-volt power supply socket to the IP extension.
2. Install the retaining ring (3) to the 12-volt power supply socket (2).
3. Connect the electrical connectors (1) to the 12-volt power supply socket.
4. Install the IP extension.
5. Connect the negative battery cable.
"For a description of the RPO Code(s) shown in this article or any of the images therein, refer to the RPO Code List found at Vehicle/Application ID". RPO Codes