HVAC Control Components
HVAC CONTROL ASSEMBLYAir Temperature Description And Operation:
The HVAC control assembly is a non-class 2 device that interfaces between the operator and the HVAC system to maintain air temperature and distribution settings. The ignition 3 voltage circuits provide power to the control assembly. Two integrated potentiometers control air temperature door position and blower motor speed. The integrated vacuum system controls the mode door position. The control assembly supports the features.
AUXILIARY HVAC CONTROL PROCESSOR
The auxiliary HVAC control processor controls all outputs for the auxiliary HVAC system. The auxiliary HVAC control processor receives inputs from the front and rear auxiliary HVAC control assemblies. The auxiliary HVAC control processor does not utilize Class 2 communications.
If the auxiliary HVAC control processor receives a 12 volt varied voltage input for an auxiliary air temperature actuator change request. Then the auxiliary HVAC control processor creates a 12 volt varied output for control of the auxiliary air temperature actuator.
AIR TEMPERATURE ACTUATOR
The air temperature actuator and auxiliary air temperature actuator are a 3 wire bi-directional electric motor. Ignition 3 voltage, ground and control circuits enable the actuator to operate. The control circuit uses a 0-12 volt linear-ramped signal to command the actuator movement. The 0 and 12 volt control values represent the opposite limits of the actuator range of motion. The values in between 0 and 12 volts correspond to the positions between the limits.
When the HVAC control assembly sets a commanded, or targeted, value, the control signal is set to a value between 0-12 volts. The actuator shaft rotates until the commanded position is reached. The module will maintain the control value until a new commanded value is needed.
A/C PRESSURE SWITCHES
The A/C system is protected by two A/C pressure switches.
^ A/C low pressure switch
^ A/C high pressure switch
The A/C high pressure switch interrupts the A/C request signal when the A/C line pressure is more than a predetermined value. The A/C low pressure switch interrupts the A/C low pressure switch signal when the A/C line pressure is less than or more than a predetermined value. When the Powertrain Control Module (PCM) stops receiving the required signals, the A/C compressor clutch relay control circuit is no longer grounded, disengaging the A/C compressor clutch. The A/C compressor clutch is disengaged under the following conditions:
^ A/C low pressure switch is less than 124 kPa (18 psi).
^ A/C low pressure switch is more than 338 kPa (49 psi).
^ A/C high pressure switch is more than 2896 kPa (420 psi).
BYPASS VALVES
The bypass valves included in the air temperature system are:
^ Coolant Bypass Valve
^ Hot Water Bypass Valve
The bypass valve is a normally open valve, which closes when vacuum is applied to the valve. When the MAX A/C mode is selected, vacuum from the HVAC control assembly is applied to the bypass valve. The vacuum must be strong enough to overcome the tension of the valve's internal return spring in order to close the bypass valve. The return spring forces the valve to return to the open position, when any of the other HVAC modes are selected. In the closed position, the flow of coolant to the heater core is bypassed, allowing maximum cooling to the passenger compartment.