Recirculation Door Replacement (Delphi)
REMOVAL PROCEDURE1. Remove the HVAC module assembly. Service and Repair
2. Disconnect the recirculation actuator electrical connection (1).
3. Remove the recirculation actuator mounting screws.
4. Remove the recirculation actuator.
5. Remove the recirculation door.
INSTALLATION PROCEDURE
1. Install the recirculation door.
2. Install the recirculation actuator.
3. Install the recirculation actuator mounting screws.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the screws to 1.9 N.m (17 lb in).
4. Connect the recirculation actuator electrical connection (1).
5. Install the HVAC module assembly.