Recirculation Door Replacement (Heat Only)
REMOVAL PROCEDURE1. Remove the heater/vent module. Service and Repair
2. Disconnect the recirculation actuator electrical connection (1).
3. Remove the recirculation actuator mounting screws.
4. Remove the recirculation actuator.
5. Remove the recirculation door.
INSTALLATION PROCEDURE
1. Install the recirculation door.
2. Install the recirculation actuator.
3. Install the recirculation actuator mounting screws.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the screws to 1.9 N.m (17 lb in).
4. Connect the recirculation actuator electrical connection (1).
5. Install the heater/vent module.