Inflatable Restraint Instrument Panel Module Replacement
REMOVAL PROCEDURE1. Disable the SIR system. Refer to SIR Disabling and Enabling Zone 5.
CAUTION:
- Refer to SIR Caution in Service Precautions.
- Refer to SIR Inflator Module Handling and Storage Caution in Service Precautions.
2. Remove the right knee bolster.
3. Remove the connector position assurance (CPA) retainer (2) from the inflatable restraint I/P module harness connector.
4. Disconnect the inflatable restraint I/P module connector (1).
5. Remove the clip that retains the inflatable restraint I/P module harness to the I/P (3).
6. Remove the 2 bolts (2) that retain the inflatable restraint I/P module (3) to the I/P carrier.
7. Push out from the back side in order to remove the inflatable restraint I/P module from the I/P.
8. Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Inflator Module Handling and Scrapping.
INSTALLATION PROCEDURE
1. Install the inflatable restraint I/P module (3).
2. Install the 2 bolts (2) that retain the inflatable restraint I/P module to the I/P carrier.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the bolts to 9 N.m (80 lb in).
3. Install the inflatable restraint I/P module connector (1).
4. Install the CPA retainer (2).
5. Install the clip that retains the inflatable restraint I/P module harness to the I/P (3).
6. Install the right knee bolster.
7. Enable the SIR system. Refer to SIR Disabling and Enabling Zone 5.