Operation CHARM: Car repair manuals for everyone.

Instrument Panel Module Replacement

INFLATABLE RESTRAINT INSTRUMENT PANEL MODULE REPLACEMENT

REMOVAL PROCEDURE

CAUTION:
- Refer to SIR Inflator Module Handling and Storage Caution in Service Precautions.
- Refer to SIR Caution in Service Precautions.


1. Disable the SIR system. Refer to SIR Disabling and Enabling Zone 5.
2. Remove the right knee bolster bracket.
3. Remove the passenger instrument panel (I/P) trim pad.
4. Remove the body control module.




5. Remove the connector position assurance (CPA) from the harness connector on the inflatable restraint I/P module.
6. Disconnect the I/P module electrical connector (1).




7. Remove the upper bolts (3) from the I/P module (1).
8. Remove the lower bolts (2) from the I/P module (1).
9. Remove the I/P module (1).
10. Ensure that the I/P module is fully deployed before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Inflator Module Handling and Scrapping.

INSTALLATION PROCEDURE




1. Install the inflatable restraint I/P module (1) to the I/P carrier.

NOTE: Refer to Fastener Notice in Service Precautions.

2. Install the lower bolts (2) hand tight.
3. Install the lower bolts (3) to the inflatable restraint I/P module.

Tighten
Tighten the bolts to 10 N.m (89 lb in).




4. Install the right knee bolster bracket.
5. Install the passenger I/P trim pad.
6. Connect the electrical connector (1) to the inflatable restraint I/P module.
7. Install the CPA to the I/P module electrical connector.
8. Install the body control module.
9. Enable the SIR system. Refer to SIR Disabling and Enabling Zone 5.