Fuel Level Sensor: Service and Repair
FUEL LEVEL SENSOR REPLACEMENTREMOVAL PROCEDURE
1. Remove the fuel sending unit.
2. Push in the retainer in order to disengage the electrical connector.
3. Remove the fuel level sensor electrical connector.
4. Push the locking tangs (1) in towards the interior of the sending unit bucket.
5. Slide the fuel level sensor up and out from the sending unit bucket.
INSTALLATION PROCEDURE
1. Slide the fuel level sensor down in order to install the sensor to the sending unit bucket.
2. Ensure that the locking tangs (1) are engaged.
3. Install the fuel level sensor electrical connector.
4. Ensure that the retainer is completely engaged.
5. Install the fuel sending unit.