Generator Replacement - Auxiliary
GENERATOR REPLACEMENT - AUXILIARY
REMOVAL PROCEDURE
CAUTION: Refer to Battery Disconnect Caution in Service Precautions.
1. Disconnect the negative battery cable.
2. Disconnect the auxiliary generator electrical connector (3).
3. Remove the drive belt.
4. Remove the positive cable from the auxiliary generator, perform the following:
1. Slide the boot (4) down to access the terminal stud.
2. Remove the positive cable nut (1).
3. Remove the positive cable.
5. Remove the auxiliary generator bolts (3).
6. Remove the auxiliary generator (4).
INSTALLATION PROCEDURE
1. Install the auxiliary generator (4).
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the auxiliary generator bolts (3).
Tighten the bolts to 50 N.m (37 lb ft).
3. Install the positive cable to the auxiliary generator, perform the following:
1. Install the positive cable.
2. Install the positive cable nut (1).
Tighten the nut to 9 N.m (80 lb in).
3. Slide the boot (4) up to cover the terminal stud.
4. Install the drive belt.
5. Connect the auxiliary generator electrical connector (3).
6. Connect the negative battery cable.