Generator Cable Replacement
Generator Cable Replacement
Removal Procedure
Caution: Refer to Battery Disconnect Caution.
1. Disconnect the negative battery cable.
2. If necessary, remove the engine sight shield.
3. Remove the generator cable from the generator, perform the following:
1. Reposition the boot to expose the stud.
2. Remove the generator cable nut.
3. Remove the generator cable from the stud.
4. Open the positive cable junction block.
5. Remove the generator cable nut.
6. Remove the generator cable (2) from the junction block.
Installation Procedure
Notice: Refer to Fastener Notice.
1. Install the generator cable (2) to the junction block.
2. Install the generator cable nut.
Tighten the nut to 9 N.m (80 lb in).
3. Close the positive cable junction block.
4. Install the generator cable to the generator, perform the following:
1. Install the generator cable to the stud.
2. Install the generator cable nut.
Tighten the nut to 9 N.m (80 lb in).
3. Position the boot to cover the stud.
5. If necessary, install the engine sight shield.
6. Connect the negative battery cable.