Operation CHARM: Car repair manuals for everyone.

P0134



DTC P0134 or P0154

CIRCUIT DESCRIPTION
Heated oxygen sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content in the exhaust stream. The HO2S must reach operating temperature to provide an accurate voltage signal. Heating elements inside the HO2S minimize the time required for the sensors to reach operating temperature. The powertrain control module (PCM) supplies the HO2S with a reference, or bias, voltage of about 450 mV. When the engine is first started, the PCM operates in Open Loop, ignoring the HO2S voltage signal. Once the HO2S reaches operating temperature and Closed Loop is achieved, the HO2S generates a voltage within a range of 0-1,000 mV that fluctuates above and below bias voltage. High HO2S voltage indicates a rich exhaust stream. Low HO2S voltage indicates a lean exhaust stream. If the PCM detects that the HO2S voltage remains within the bias voltage range, DTC P0134 sets for HO2S bank 1 sensor 1 or DTC P0154 sets for HO2S bank 2 sensor 1.

DTC DESCRIPTORS
This diagnostic procedure supports the following DTCs:
- DTC P0134 HO2S Circuit Insufficient Activity Bank 1 Sensor 1
- DTC P0154 HO2S Circuit Insufficient Activity Bank 2 Sensor 1

CONDITIONS FOR RUNNING THE DTC
- DTCs P0068, P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0128, P0169, P0178, P0179, P0200, P0220, P0442, P0446, P0452, P0453, P0455, P0496, P1125, P1258, P1516, P2101, P2108, P2135, U0107 are not set.
- The Engine Run Time parameter is more than 300 seconds.
- The Fuel Alcohol content parameter is less than 90 percent.
- The Ignition 1 Signal parameter is between 10-18 volts.
- This diagnostic runs continuously when the above conditions are met.

CONDITIONS FOR SETTING THE DTC
The PCM detects that the affected HO2S voltage parameter is between 350-550 mV for 60 seconds.

ACTION TAKEN WHEN THE DTC SETS
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.
- The control module commands the Loop Status open.

CONDITIONS FOR CLEARING THE MIL/DTC
- The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
- A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
- A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
- Clear the MIL and the DTC with a scan tool.

TEST DESCRIPTION

Step 1 - Step 7:




Step 8 - Step 18:




The number below refers to the step number on the diagnostic table.
3. If the voltage is varying above and below the specified value, the condition is not present.