112. Exhaust Gas Recirculation Valve and Cooler Installation
Exhaust Gas Recirculation and Cooler Installation
1. Install the intake manifold tube.
2. Install the exhaust gas recirculation (EGR) cooler bracket.
3. Notice: Refer to Fastener Notice in Service Precautions.
Install the EGR cooler bracket bolts.
Tighten the EGR cooler bracket bolts to 25 Nm (18 ft. lbs.).
4. Install the EGR and cooler.
5. Install the EGR mount bolt.
Tighten the EGR mount bolt to 50 Nm (37 ft. lbs.).
6. Install the top EGR cooler bolts.
Tighten the top EGR cooler bolts to 25 Nm (18 ft. lbs.).
7. Install the air inlet tube.
8. Install the air inlet tube nuts.
Tighten the air inlet tube nuts to 25 Nm (18 ft. lbs.).
9. Install the air inlet tube to intake manifold tube bolt and nut.
Tighten the air inlet tube to intake manifold tube bolt and nut to 25 Nm (18 ft. lbs.).