Installation
Engine Coolant Temperature (ECT) SensorInstallation
1. Apply Loctite 262 or equivalent to the threads of the ECT sensor, and tighten it to the specified torque.
Tightening torque: 25 N.m (18 lb.ft)
2. Connect the harness connector to the ECT sensor.
3. Replenish the cooling water.
- Refer to 'Reference (cooling water replenishment procedure)' part of 'Cooling System'.