Floor Air Outlet Duct Replacement - Right Side



Floor Air Outlet Duct Replacement - Right Side

Removal Procedure




1. Remove the HVAC module assembly.
2. Remove the floor air outlet duct retaining screws (2, 3, 4).
3. Remove the RH side floor air outlet duct (1).

Installation Procedure




1. Install the floor air outlet duct (1) into position.

Notice: Refer to Fastener Notice.

2. Install the floor air outlet duct retaining screws (2, 3, 4).

Tighten the screws to 1.9 N.m (17 lb in).