Recirculation Door Replacement
Recirculation Door Replacement
Tools Required
J 39400-A Electronic Halogen Leak Detector
Removal Procedure
1. Remove the evaporator and blower module assembly front cover (3).
2. Remove the recirculation door actuator (7) and the linkage.
3. Remove the recirculation door (1) from the evaporator and blower module assembly.
Installation Procedure
1. Install the recirculation door (1) to the evaporator and blower module assembly.
2. Install the recirculation door actuator (7) and the linkage.
3. Install the evaporator and blower module assembly cover (3).
4. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
5. Leak test the fittings of the component replaced using the J 39400-A.