Air Cleaner Housing: Service and Repair
Air Cleaner Assembly Replacement
Removal Procedure
1. Loosen the air cleaner outlet resonator clamp (1) at the mass air flow (MAF)/intake air temperature (IAT) sensor.
2. Remove the air cleaner outlet resonator from the MAF/IAT sensor.
3. Disconnect the engine wiring harness electrical connector (1) from the MAF/IAT sensor.
4. Remove the air cleaner by pulling upward until the mounting studs are free from the grommets.
Installation Procedure
1. Install the air cleaner by pressing downward until the grommets are seated.
2. Connect the engine wiring harness electrical connector (1) to the MAF/IAT sensor.
3. Install the air cleaner outlet resonator to the MAT/IAT sensor.
Notice: Refer to Fastener Notice.
4. Tighten the air cleaner outlet resonator clamp (1) at the MAF/IAT sensor.
Tighten the clamp to 4 N.m (35 lb in).