DTC B1008
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. Initial Inspection and Diagnostic Overview
* Review Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions provides an overview of each diagnostic category.
DTC Descriptor
DTC B1008 42
- Calibration Data Not Programmed
Circuit/System Description
When the ignition is turned ON, the object alarm module performs a self-test to verify if any critical malfunction exists within the system. When the object alarm system has completed the power-up mode, the object alarm module establishes communication with the body control module (BCM). During the power-up mode the object detection module checks for a valid calibration data set, if no valid calibration set is found, the object alarm module disables the system and commands the red indicator ON.
Conditions for Running the DTC
Ignition voltage is between 9-16 volts.
Conditions for Setting the DTC
When the calibration data set is not programmed in the object alarm module upon startup.
Action Taken When the DTC Sets
* The object alarm module commands red LED ON.
* The object alarm module will send a serial data communication message to the instrument panel cluster (IPC) to display SERVICE PARK ASSIST message on the driver information center (DIC) and the chime sounds.
Conditions for Clearing the DTC
* The DTC becomes history when the conditions for setting the DTC are no longer present.
* The history DTC clears after 100 malfunction-free ignition cycles.
Circuit/System Verification
Verify that DTC B1008 is not set.
If the DTC resets, replace the object alarm module.
Repair Instructions
Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests