Fluid Pan, A/T
The holes in the control valve body cover wiring connector hole seal must face toward the control solenoid valve assembly. If the holes face toward the valve body cover, there is a potential for a leak around the seal.
Install all control valve body cover bolts and studs by hand then torque all bolts and studs in sequence.
Install the 12 control valve body cover bolts (1) M6 x 30.
Tighten the bolts in sequence to 12 Nm (106 lb in).
Install the 2 control valve body cover studs (2) M6 x 30.
Tighten the studs in sequence to 12 Nm (106 lb in).